• +919998843324
  • info@maheshfabricators.com
  • ISO 9001-2015 Certified Company
Axial Flow Fan Heater Blower Unit

Axial Flow Fan Heater Blower Unit

Introduction

An Axial Flow Fan Heater Blower Unit is a specialized air-moving system designed to combine high airflow with controlled heating—making it ideal for ventilation, drying, and temperature regulation in industrial, commercial, and HVAC applications. Whether you're in textiles, food processing, paint booths, greenhouses, or warehouse heating, this unit is essential for efficient air distribution with thermal control.

As a trusted Axial Flow Fan Heater Blower Unit manufacturer and supplier, we offer units that are engineered for reliability, energy efficiency, and durability in challenging environments. Built with industrial-grade materials and advanced motor configurations, our systems ensure uniform airflow, quick heating response, and long-term cost savings.


Best Features of Our Axial Flow Fan Heater Blower Unit

FeatureDescription
High Air Delivery OutputDelivers large air volumes over long distances for effective heat dispersion.
Integrated Heating SystemElectric heaters or steam coil integration for quick, controlled warming.
Heavy-Duty Motor AssemblyMotors are IP55 rated and built to run continuously without overheating.
Aerodynamic Fan Blade DesignSpecially designed blades reduce noise and increase efficiency.
Temperature Control OptionsComes with adjustable thermostats or PLC control panels.
Robust Casing                                                                  Powder-coated or stainless steel body resists corrosion and harsh conditions.
Mounting VersatilityCan be installed on walls, ducts, or portable stands based on application.
Energy-Efficient OperationOptimized for low power consumption per CFM output.

Best Benefits of Our Axial Flow Fan Heater Blower Units
BenefitImpact / Business Advantage
Fast & Uniform Air DistributionImproves thermal comfort and drying speed in large spaces.
Dual Function (Fan + Heater)Saves space and simplifies system design.
Operational Cost Efficiency                                           High airflow with less energy use reduces electricity bills.
Easy Installation & MaintenancePlug-and-play wiring and removable panels allow quick servicing.
Customizable ConfigurationSuited for specific CFM, pressure, and heat load needs.
Eco-Friendly OptionsAvailable with low-emission heating elements and recyclable components.

Why Choose Us?
  • In-House Manufacturing Expertise
    Every fan blower unit is designed and fabricated at our own facility, ensuring strict quality control.

  • Custom-Built for Your Industry
    We build units tailored to specific industries like pharmaceuticals, greenhouses, textiles, and warehouses.

  • Advanced Engineering Support
    Our team helps in airflow calculation, heat load estimation, and duct compatibility analysis.

  • Pan-India Delivery & Global Exports
    Efficient logistics ensure quick shipping to your site across India or overseas markets.

  • Comprehensive After-Sales Service
    Includes installation guidance, warranty, replacement parts, and remote technical support.

  • Proven Reliability
    Our blower units are installed in over 500+ industrial plants and commercial facilities globally.


Conclusion

Choosing the right Axial Flow Fan Heater Blower Unit can significantly enhance the airflow and thermal efficiency of your facility. Our systems combine industrial-grade durability, customizable options, and superior performance, helping you achieve consistent heating and ventilation in even the most demanding environments.

Whether you’re upgrading your HVAC systems, installing ventilation for a new facility, or enhancing drying processes, our units offer the ideal mix of power, precision, and longevity.


Frequently Asked Questions (FAQs)

1. What is an axial flow fan heater blower unit used for?

This unit is designed to deliver large volumes of air with added heating functionality. It's commonly used in warehouses, factories, greenhouses, and HVAC setups to provide heated airflow for comfort, drying, or process control. The axial design ensures straight-line airflow, ideal for large or open spaces.


2. How does this unit differ from a standard blower or heater?

Unlike standard blowers or standalone heaters, an axial flow fan heater blower combines the two functions—offering high airflow with heating in a compact, energy-efficient form. This integration allows for better temperature control and air distribution from a single device.


3. What are the heating options available in your units?

Our units can be configured with:

  • Electric resistance heaters (for dry heat environments)

  • Steam or hot water coils (for process plants or centralized systems)

  • PTC ceramic heaters (for energy-saving operations)
    Each option is selected based on the environment, energy availability, and airflow needs.


4. Can this unit be used in ducted systems?

Yes, our axial flow fan heater blower units can be:

  • Directly mounted to ducts

  • Installed on walls or ceilings

  • Used in open spaces with a free discharge
    We provide mounting frames, vibration isolators, and duct collars as needed.


5. What materials are used in the construction of the unit?

Depending on the application, we offer:


6. Is there a risk of overheating or safety hazards?

No, the unit is equipped with:

  • Thermostats and thermal overload protectors

  • High-temperature cut-off switches

  • Optional flame-retardant housings for sensitive environments
    These features make it safe for 24/7 operation.


7. What power requirements do your blower units need?

Standard power supply is:

  • Single-phase 230V for smaller units

  • Three-phase 415V for industrial-grade units
    Power consumption varies by airflow capacity and heating load, ranging from 2 kW to 20+ kW.


8. Can it be used for drying applications?

Absolutely. These units are used in:

  • Paint drying booths

  • Paper and textile drying lines

  • Agricultural produce drying
    The consistent, warm air output ensures quick and uniform drying without damage to materials.


9. What is the maintenance frequency?

Maintenance is minimal and includes:

  • Cleaning fan blades quarterly

  • Checking electrical connections every 6 months

  • Replacing heating elements after 3–5 years (based on usage)
    We offer AMC (Annual Maintenance Contracts) for worry-free operation.


10. How do I select the right model for my application?

Selection is based on:

  • Required airflow (CFM)

  • Heating capacity (kW)

  • Duct size or mounting constraints

  • Ambient vs. target temperature
    Our engineers can perform a free assessment and recommend the right unit for your specific needs.